Skip to content
RadField UltraPort 90
RadField Imaging Systems Model: UP-90-PRO

Equipment Review Score

Transparent multi-metric evaluation criteria

8.7/ 10
Sample Test Score
Build & Design 8.8
Portability & Footprint 9.6
Diagnostic Features 8.4
Connectivity & DICOM 8.7
Workflow & Usability 8.9
Documentation & Service 8.0
Capital Equipment Value 8.2
Methodology: Bench testing & public specification audits Unbiased Review Metric
RadField Imaging Systems· Portable X-Ray· Introduced 2025

RadField UltraPort 90

A lightweight 2.4 kW battery-powered portable X-ray unit designed for austere environments, sports medicine sideline evaluations, and urgent home healthcare visits.

Power Output 2.4 kW High-Frequency Monoblock (Sample Spec)
Detector Type Wireless CsI Flat Panel
Weight 7.8 kg (17.2 lbs) generator body
Price Range $22,000 – $29,000 (Sample Range)
Warranty 2-Year Standard Manufacturer Limited Warranty
Data Status Sample/Demo Model

Full Technical Specifications

10 Parameters
Specification Details & Rating Status
Product Type High-Frequency Portable X-Ray Generator Verified
Generator Output 2.4 kW (40–90 kVp, 0.4–30 mAs) [Sample] Sample / Unverified
Focal Spot Size 0.8 mm x 0.8 mm stationary anode Verified
Unit Weight 7.8 kg generator; stand adds 11.2 kg Verified
Battery Capacity Approx. 250 exposures per charge (70kVp/4mAs) [Sample] Sample / Unverified
Collimator LED manual collimator with crosshair timer Verified
DICOM Modality Worklist Supported via embedded acquisition console Verified
Cooling Rate Not publicly specified — verify with manufacturer Sample / Unverified
Radiation Leakage < 0.88 mGy/h at 1 meter at maximum rating Verified
Warranty 24 Months parts and labor Verified
Specifications subject to manufacturer engineering revisions ISO / IEC Conformity

Strengths and Limitations

✓

Advantages & Strengths

  • •Class-leading generator power-to-weight ratio under 8 kg
  • •Dual hot-swappable lithium iron phosphate (LiFePO4) battery packs
  • •Integrated touch interface with pre-programmed anatomical body part programs (APPs)
  • •Sub-3-second wireless image transfer to tablet acquisition console
✕

Limitations & Trade-Offs

  • •Output limited to 90 kVp / 30 mAs (unsuitable for bariatric lumbar spines)
  • •Optional carbon-fiber carrying case sold separately
  • •Battery recharge time is 90 minutes when completely depleted

Clinical Deployment Context

Suitable Environments
  • •Sports medicine sidelines and mobile athletic training facilities
  • •Disaster response, field triage hospitals, and military forward bases
  • •Rural urgent care clinics lacking dedicated lead-lined suites
  • •Home health and nursing facility visiting radiology services
Detector Interoperability

Universal 14x17 inch and 10x12 inch wireless flat-panel detectors with automatic exposure detection (AED) or hardwired sync cable.