Claritas Medical Imaging
Model: CPS-650-FL
Equipment Review Score
Transparent multi-metric evaluation criteria
9.1/ 10
Sample Test Score
Build & Design
9.2
Portability & Footprint
5.0
Diagnostic Features
9.3
Connectivity & DICOM
9.5
Workflow & Usability
9.4
Documentation & Service
9.0
Capital Equipment Value
8.6
Methodology: Bench testing & public specification audits
Unbiased Review Metric
Claritas Medical Imaging·
Digital X-Ray·
Introduced 2024
Claritas Pro Suite 65
A robust 65 kW floor-mounted digital radiography room suite configured for mid-to-high volume outpatient orthopedic and hospital diagnostic departments.
Power Output
65 kW High-Frequency Generator (Sample Spec)
Detector Type
Integrated Fixed DR
Weight
Floor track and stand: 380 kg total footprint
Price Range
$85,000 – $135,000 (Sample Range)
Warranty
3-Year Comprehensive Capital Equipment Warranty
Data Status
Sample/Demo Model
Full Technical Specifications
10 Parameters| Specification | Details & Rating | Status |
|---|---|---|
| Product Type | Fixed Floor-Mounted Digital Radiography Room Suite | Verified |
| Generator Output | 65 kW (40–150 kVp, 10–800 mA) [Sample] | Sample / Unverified |
| Tube Anode Heat Storage | 400,000 Heat Units (HU) dual-focus 0.6 / 1.2 mm | Verified |
| Patient Table Weight Limit | 295 kg (650 lbs) motorized elevation | Verified |
| Detectors Included | Dual 17x17 inch CsI Flat Panel Detectors (Table + Wall) | Verified |
| Image Preview Time | < 2.5 seconds to local acquisition workstation | Verified |
| Grid Type | Removable 10:1 anti-scatter grid with 40 lp/cm line rate | Verified |
| Power Requirements | 3-Phase 380-480 VAC, 50/60 Hz | Verified |
| Room Dimensions Required | Minimum recommended 4.2m x 3.6m (14ft x 12ft) | Verified |
| Warranty | 36 Months parts and glass tube coverage | Verified |
Specifications subject to manufacturer engineering revisions
ISO / IEC Conformity
Strengths and Limitations
✓
Advantages & Strengths
- •Heavy-duty floor-mounted rail eliminates ceiling grid structural reinforcement costs
- •Motorized auto-tracking between tube head and vertical chest Bucky stand
- •High heat-capacity X-ray tube (400 kHU) prevents thermal bottlenecks in busy clinics
- •Elevating 4-way floating tabletop rated for 295 kg (650 lbs) patient capacity
✕
Limitations & Trade-Offs
- •Requires 3-phase 480V or dedicated 100A line power conditioner
- •Minimum ceiling height requirement of 2.75 meters (9 feet)
- •Substantial lead shielding required in walls due to 65 kW high-output rating
Clinical Deployment Context
Suitable Environments
- •High-throughput hospital radiology departments and trauma bays
- •Specialized orthopedic surgery clinics and spine treatment centers
- •Regional outpatient multi-modality diagnostic imaging facilities
Detector Interoperability
Dedicated dual 17x17-inch Cesium Iodide (CsI) wireless or tethered panels integrated with acquisition station.
