Skip to content
QuantumDirect 1417 GadOx Retrofit FPD
QuantumDirect Imaging Model: QD-1417-G

Equipment Review Score

Transparent multi-metric evaluation criteria

8.6/ 10
Sample Test Score
Build & Design 8.4
Portability & Footprint 8.8
Diagnostic Features 8.3
Connectivity & DICOM 8.5
Workflow & Usability 8.6
Documentation & Service 8.7
Capital Equipment Value 9.4
Methodology: Bench testing & public specification audits Unbiased Review Metric
Official Manufacturer Documentation ↗
QuantumDirect Imaging· X-Ray Detectors· Introduced 2024

QuantumDirect 1417 GadOx Retrofit FPD

A value-engineered Gadolinium Oxysulfide (GadOx / GOS) flat panel detector offering an affordable direct DR upgrade path for budget-constrained private practices.

Power Output N/A (Li-ion Rechargeable)
Detector Type GadOx Flat Panel
Weight 3.1 kg (6.8 lbs)
Price Range $9,500 – $13,500 (Sample Range)
Warranty 2-Year Standard Manufacturer Protection
Data Status Sample/Demo Model

Full Technical Specifications

8 Parameters
Specification Details & Rating Status
Scintillator Type Gadolinium Oxysulfide: Terbium (Gd2O2S:Tb / GadOx) Verified
Active Area 14 x 17 inches (350 mm x 430 mm) Verified
Pixel Pitch 140 microns [Sample] Sample / Unverified
DQE @ 0 lp/mm ~48% at standard beam quality (Sample) Sample / Unverified
A/D Conversion 14-bit grayscale depth Verified
Battery Duration Up to 6 hours active continuous use Verified
Weight 3.1 kg (6.8 lbs) Verified
Warranty 24 Months limited replacement warranty Verified
Specifications subject to manufacturer engineering revisions ISO / IEC Conformity

Strengths and Limitations

✓

Advantages & Strengths

  • •Most accessible price point for clinics transitioning away from slow film chemical processors or CR
  • •Tough, moisture-resistant phosphor coating provides high physical resilience
  • •Reliable Automatic Exposure Detection (AED) functions with virtually any existing X-ray generator
  • •Fits standard 14x17 inch Bucky without requiring cabinetry modifications
✕

Limitations & Trade-Offs

  • •Lower DQE (~48% @ 0 lp/mm) compared to Cesium Iodide requires slightly higher radiation dose
  • •Image sharpness is marginally softer than needle-grown CsI scintillators
  • •Wi-Fi standard limited to 802.11ac rather than newer Wi-Fi 6

Clinical Deployment Context

Suitable Environments
  • •Small private chiropractic, podiatry, and primary care clinics
  • •Developing market regional clinics upgrading from manual wet-film tanks
  • •Backup/secondary detector in veterinary animal clinics
Detector Interoperability

Universal AED trigger compatible with generators from 10 kW to 80 kW.