Skip to content
VisiRay 1717-DR High-DQE Flat Panel
VisiRay Medical Sensors Model: VR-1717-CSI

Equipment Review Score

Transparent multi-metric evaluation criteria

9.2/ 10
Sample Test Score
Build & Design 9.3
Portability & Footprint 8.4
Diagnostic Features 9.4
Connectivity & DICOM 9.6
Workflow & Usability 9.5
Documentation & Service 9.0
Capital Equipment Value 8.7
Methodology: Bench testing & public specification audits Unbiased Review Metric
VisiRay Medical Sensors· X-Ray Detectors· Introduced 2025

VisiRay 1717-DR High-DQE Flat Panel

A full-format 17x17 inch wireless Cesium Iodide flat panel detector that eliminates the need to rotate cassettes between portrait and landscape chest exams.

Power Output N/A (Battery or Tethered Power)
Detector Type Wireless CsI Flat Panel
Weight 3.3 kg (7.27 lbs)
Price Range $16,000 – $22,000 (Sample Range)
Warranty 3-Year Manufacturer Warranty with accidental drop insurance
Data Status Sample/Demo Model

Full Technical Specifications

10 Parameters
Specification Details & Rating Status
Active Matrix 17 x 17 inches (432 mm x 432 mm) Verified
Scintillator Type Needle-grown Cesium Iodide (CsI) Verified
Pixel Pitch 139 microns [Sample] Sample / Unverified
A/D Resolution 16-bit true grayscale dynamic range Verified
Spatial Resolution 3.6 lp/mm limiting resolution Verified
DQE Rating 74% at 0 lp/mm (Sample Test Value) Sample / Unverified
Weight 3.3 kg (7.3 lbs) Verified
Battery Run Time 8.5 hours active operation with dual-cell Li-ion pack Verified
Drop Rating 1.2 meter drop resistance on steel face Verified
Warranty 36 Months standard coverage Verified
Specifications subject to manufacturer engineering revisions ISO / IEC Conformity

Strengths and Limitations

✓

Advantages & Strengths

  • •Square 17x17 inch active area eliminates detector rotation when alternating chest and abdomen projections
  • •Direct-deposited CsI scintillator delivers top-tier 74% DQE @ 0 lp/mm
  • •6 GHz Wi-Fi 6E band avoids clinical network congestion in high-traffic hospital RF environments
  • •Continuous magnetic auto-docking power in table Bucky with hot-swap battery capability
✕

Limitations & Trade-Offs

  • •Slightly heavier than 14x17 inch panels when performing freehand extremity views
  • •Thicker border bezel than minimal 14x17 cassettes
  • •Higher price point than GadOx alternative

Clinical Deployment Context

Suitable Environments
  • •Fixed chest stands and radiographic tables in hospital emergency rooms
  • •Outpatient imaging centers with heavy daily chest and spine workload
Detector Interoperability

Standard Bucky trays with automatic AED generator triggering.