Lumina 1417-CsI Wireless DR Panel
Lumina Imaging Components Model: FPD-1417-PRO

Equipment Review Score

Transparent multi-metric evaluation criteria

9.2/ 10
Sample Test Score
Build & Design 9.5
Portability & Footprint 9.3
Diagnostic Features 9.1
Connectivity & DICOM 9.4
Workflow & Usability 9.2
Documentation & Service 8.8
Capital Equipment Value 8.9
Methodology: Bench testing & public specification audits Unbiased Review Metric
Lumina Imaging Components· X-Ray Detectors· Introduced 2025

Lumina 1417-CsI Wireless DR Panel

A direct-deposit Cesium Iodide (CsI) wireless flat panel detector engineered for cassette-tray retrofit upgrades and low-dose clinical imaging.

Power Output N/A (Rechargeable Li-ion 4,800 mAh)
Detector Type Wireless CsI Flat Panel
Weight 2.8 kg (6.17 lbs) including battery
Price Range $14,000 – $19,500 (Sample Range)
Warranty 3-Year Drop & Liquid Ingress Manufacturer Protection
Data Status Sample/Demo Model

Full Technical Specifications

10 Parameters
Specification Details & Rating Status
Scintillator Material Thallium-doped Cesium Iodide (CsI:Tl) Verified
Active Area 14 x 17 inches (358 mm x 430 mm) Verified
Pixel Pitch 100 micrometers (microns) [Sample] Sample / Unverified
Pixel Matrix 3580 x 4300 active pixels Verified
DQE @ 0 lp/mm ~72% at RQA5 beam quality [Sample] Sample / Unverified
A/D Conversion 16-bit high-dynamic range Verified
Battery Life Up to 9.5 hours operational standby / 1,400 images Verified
Mechanical Load Limit 150 kg point load / 300 kg distributed uniform load Verified
Weight 2.8 kg (6.2 lbs) Verified
Ingress Protection IP67 rated water and particulate resistant Verified
Specifications subject to manufacturer engineering revisions ISO / IEC Conformity

Strengths and Limitations

✓

Advantages & Strengths

  • •Direct-deposited needle-structure CsI scintillator yields high DQE at low patient doses
  • •Standard ISO 4090 cassette dimensions fit into existing film/CR Bucky trays without modification
  • •IP67 dust and immersion water resistance protects against clinical fluid spills
  • •Internal memory buffers up to 200 radiographic images in case of Wi-Fi dropouts
✕

Limitations & Trade-Offs

  • •Higher upfront acquisition cost compared to GadOx (Gadolinium Oxysulfide) alternatives
  • •Requires separate docking station for simultaneous multi-battery fast recharging
  • •Carbon-fiber surface requires approved quaternary ammonium cleaning agents

Clinical Deployment Context

Suitable Environments
  • •Cassette-sized DR retrofits in existing analog or CR radiographic rooms
  • •Mobile X-ray carts traveling through ICU and emergency wards
  • •Trauma bays requiring rapid wireless positioning under patients
Detector Interoperability

Compatible with any X-ray generator via Automatic Exposure Detection (AED) with zero generator interface wiring.