Skip to content
Claritas Pro Suite 65
Claritas Medical Imaging Model: CPS-650-FL

Equipment Review Score

Transparent multi-metric evaluation criteria

9.1/ 10
Sample Test Score
Build & Design 9.2
Portability & Footprint 5.0
Diagnostic Features 9.3
Connectivity & DICOM 9.5
Workflow & Usability 9.4
Documentation & Service 9.0
Capital Equipment Value 8.6
Methodology: Bench testing & public specification audits Unbiased Review Metric
Claritas Medical Imaging· Digital X-Ray· Introduced 2024

Claritas Pro Suite 65

A robust 65 kW floor-mounted digital radiography room suite configured for mid-to-high volume outpatient orthopedic and hospital diagnostic departments.

Power Output 65 kW High-Frequency Generator (Sample Spec)
Detector Type Integrated Fixed DR
Weight Floor track and stand: 380 kg total footprint
Price Range $85,000 – $135,000 (Sample Range)
Warranty 3-Year Comprehensive Capital Equipment Warranty
Data Status Sample/Demo Model

Full Technical Specifications

10 Parameters
Specification Details & Rating Status
Product Type Fixed Floor-Mounted Digital Radiography Room Suite Verified
Generator Output 65 kW (40–150 kVp, 10–800 mA) [Sample] Sample / Unverified
Tube Anode Heat Storage 400,000 Heat Units (HU) dual-focus 0.6 / 1.2 mm Verified
Patient Table Weight Limit 295 kg (650 lbs) motorized elevation Verified
Detectors Included Dual 17x17 inch CsI Flat Panel Detectors (Table + Wall) Verified
Image Preview Time < 2.5 seconds to local acquisition workstation Verified
Grid Type Removable 10:1 anti-scatter grid with 40 lp/cm line rate Verified
Power Requirements 3-Phase 380-480 VAC, 50/60 Hz Verified
Room Dimensions Required Minimum recommended 4.2m x 3.6m (14ft x 12ft) Verified
Warranty 36 Months parts and glass tube coverage Verified
Specifications subject to manufacturer engineering revisions ISO / IEC Conformity

Strengths and Limitations

✓

Advantages & Strengths

  • •Heavy-duty floor-mounted rail eliminates ceiling grid structural reinforcement costs
  • •Motorized auto-tracking between tube head and vertical chest Bucky stand
  • •High heat-capacity X-ray tube (400 kHU) prevents thermal bottlenecks in busy clinics
  • •Elevating 4-way floating tabletop rated for 295 kg (650 lbs) patient capacity
✕

Limitations & Trade-Offs

  • •Requires 3-phase 480V or dedicated 100A line power conditioner
  • •Minimum ceiling height requirement of 2.75 meters (9 feet)
  • •Substantial lead shielding required in walls due to 65 kW high-output rating

Clinical Deployment Context

Suitable Environments
  • •High-throughput hospital radiology departments and trauma bays
  • •Specialized orthopedic surgery clinics and spine treatment centers
  • •Regional outpatient multi-modality diagnostic imaging facilities
Detector Interoperability

Dedicated dual 17x17-inch Cesium Iodide (CsI) wireless or tethered panels integrated with acquisition station.